0,6 / 1kv AL / XLPE / PVC Aluminium Power Cable
Aplikasi
The 0.6 / 1kv Xlpe insulated PVC sheathed sambungan kabel kakuatan aluminium dipaké pikeun distribusi kakuatan di stasiun kakuatan, instalasi industri jeung switchgears, kitu ogé dina mains lokal.Bisa nanggung traction tangtu salila instalasi.Pikeun instalasi tetep jero taneuh.
Pangwangunan
Ciri
tegangan dipeunteun | 0.6/1kV |
Konduktor | alumunium |
Insulasi | XLPE |
Sarung | PVC |
Inti | 1, 2, 3, 4, 5, 3+1, 3+2, 4+1 |
Warna | Hideung atanapi ngaropéa |
Standar
GB / T 12706, IEC, BS, DIN sareng ICEA upami dipénta
Parameter
2 Core Aluminium Power Cable | ||||||||
Nom.Cross-bagian tina konduktor | Ketebalan insulasi | Ketebalan Sarung | Kira-kira.OD | Kira-kira Beurat | Max.Résistansi DC tina konduktor (20 ° C) | Tes Tegangan AC | Peunteun ayeuna | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV/5 mnt | Dina hawa (A) | Dina taneuh (A) |
2x4 | 0.7 | 1.8 | 11.4 | 150 | 7.41 | 3.5 | 34 | 45 |
2×6 | 0.7 | 1.8 | 12.4 | 171 | 4.61 | 3.5 | 43 | 57 |
2×10 | 0.7 | 1.8 | 14.9 | 238 | 3.08 | 3.5 | 60 | 77 |
2×16 | 0.7 | 1.8 | 17.1 | 294 | 1.91 | 3.5 | 83 | 105 |
2×25 | 0.9 | 1.8 | 20 | 394 | 1.2 | 3.5 | 105 | 125 |
2×35 | 0.9 | 1.8 | 22 | 484 | 0.868 | 3.5 | 125 | 155 |
2×50 | 1 | 1.8 | 23.4 | 497 | 0.641 | 3.5 | 160 | 185 |
2×70 | 1.1 | 1.8 | 24.5 | 640 | 0.443 | 3.5 | 200 | 225 |
2 × 95 | 1.1 | 1.9 | 28.6 | 827 | 0.32 | 3.5 | 245 | 270 |
2×120 | 1.2 | 2 | 29.7 | 1015 | 0.253 | 3.5 | 285 | 310 |
2×150 | 1.4 | 2.2 | 31.2 | 1268 | 0.206 | 3.5 | 325 | 345 |
3 Core Aluminium Power Cable | ||||||||
Nom.Cross-bagian tina konduktor | Ketebalan insulasi | Ketebalan Sarung | Kira-kira.OD | Kira-kira Beurat | Max.Résistansi DC tina konduktor (20 ° C) | Tes Tegangan AC | Peunteun ayeuna | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV/5 mnt | Dina hawa (A) | Dina taneuh (A) |
3×4 | 0.7 | 1.8 | 12 | 163 | 7.41 | 3.5 | 34 | 45 |
3×6 | 0.7 | 1.8 | 13 | 191 | 4.61 | 3.5 | 43 | 57 |
3×10 | 0.7 | 1.8 | 15.8 | 282 | 3.08 | 3.5 | 60 | 77 |
3×16 | 0.7 | 1.8 | 18.2 | 358 | 1.91 | 3.5 | 83 | 105 |
3×25 | 0.9 | 1.8 | 21.3 | 491 | 1.2 | 3.5 | 105 | 125 |
3×35 | 0.9 | 1.8 | 23.6 | 600 | 0.868 | 3.5 | 125 | 155 |
3×50 | 1 | 1.8 | 23.8 | 729 | 0.641 | 3.5 | 160 | 185 |
3×70 | 1.1 | 1.9 | 27.4 | 958 | 0.443 | 3.5 | 200 | 225 |
3 × 95 | 1.1 | 2 | 33.1 | 1242 | 0.32 | 3.5 | 245 | 270 |
3×120 | 1.2 | 2.1 | 34.7 | 1502 | 0.253 | 3.5 | 285 | 310 |
3×150 | 1.4 | 2.3 | 39.1 | 1875 | 0.206 | 3.5 | 325 | 345 |
3×185 | 1.6 | 2.4 | 42.3 | 2264 | 0.164 | 3.5 | 375 | 390 |
3×240 | 1.7 | 2.6 | 47.8 | 2861 | 0.125 | 3.5 | 440 | 450 |
3×300 | 1.8 | 2.8 | 52.4 | 3501 | 0.1 | 3.5 | 505 | 515 |
3×400 | 2 | 3.1 | 62.9 | 4627 | 0,0778 | 3.5 | 570 | 575 |
4 Core Aluminium Power Cable | ||||||||
Nom.Cross-bagian tina konduktor | Ketebalan insulasi | Ketebalan Sarung | Kira-kira.OD | Kira-kira Beurat | Max.Résistansi DC tina konduktor (20 ° C) | Tes Tegangan AC | Peunteun ayeuna | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV/5 mnt | Dina hawa (A) | Dina taneuh (A) |
4×4 | 0.7 | 1.8 | 13 | 197 | 7.41 | 3.5 | 34 | 45 |
4×6 | 0.7 | 1.8 | 14.2 | 233 | 4.61 | 3.5 | 43 | 57 |
4×10 | 0.7 | 1.8 | 17.2 | 345 | 3.08 | 3.5 | 60 | 77 |
4×16 | 0.7 | 1.8 | 19.9 | 442 | 1.91 | 3.5 | 83 | 105 |
4×25 | 0.9 | 1.8 | 23.4 | 595 | 1.2 | 3.5 | 105 | 125 |
4×35 | 0.9 | 1.8 | 25.8 | 734 | 0.868 | 3.5 | 125 | 155 |
4×50 | 1 | 1.9 | 27.2 | 912 | 0.641 | 3.5 | 160 | 185 |
4×70 | 1.1 | 2 | 27.9 | 1207 | 0.443 | 3.5 | 200 | 225 |
4×95 | 1.1 | 2.1 | 33.8 | 1569 | 0.32 | 3.5 | 245 | 270 |
4×120 | 1.2 | 2.3 | 35.8 | 1923 | 0.253 | 3.5 | 285 | 310 |
4×150 | 1.4 | 2.4 | 40.2 | 2374 | 0.206 | 3.5 | 325 | 345 |
4×185 | 1.6 | 2.6 | 43.6 | 2899 | 0.164 | 3.5 | 375 | 390 |
4×240 | 1.7 | 2.8 | 49.3 | 3670 | 0.125 | 3.5 | 440 | 450 |
4×300 | 1.8 | 3 | 54.1 | 4499 | 0.1 | 3.5 | 505 | 515 |
4×400 | 2 | 3.3 | 65.1 | 5947 | 0,0778 | 3.5 | 570 | 575 |
5 Core Aluminium Power Cable | ||||||||
Nom.Cross-bagian tina konduktor | Ketebalan insulasi | Ketebalan Sarung | Kira-kira.OD | Kira-kira Beurat | Max.Résistansi DC tina konduktor (20 ° C) | Tes Tegangan AC | Peunteun ayeuna | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV/5 mnt | Dina hawa (A) | Dina taneuh (A) |
5×4 | 0.7 | 1.8 | 14 | 223 | 7.41 | 3.5 | 34 | 45 |
5×6 | 0.7 | 1.8 | 15.3 | 266 | 4.61 | 3.5 | 43 | 57 |
5×10 | 0.7 | 1.8 | 18.7 | 395 | 3.08 | 3.5 | 60 | 77 |
5×16 | 0.7 | 1.8 | 21.7 | 512 | 1.91 | 3.5 | 83 | 105 |
5×25 | 0.9 | 1.8 | 25.6 | 700 | 1.2 | 3.5 | 105 | 125 |
5×35 | 0.9 | 1.8 | 28.3 | 872 | 0.868 | 3.5 | 125 | 155 |
5×50 | 1 | 2 | 31.6 | 1155 | 0.641 | 3.5 | 160 | 185 |
5×70 | 1.1 | 2.1 | 37.2 | 1536 | 0.443 | 3.5 | 200 | 225 |
5 × 95 | 1.1 | 2.3 | 41 | 1971 | 0.32 | 3.5 | 245 | 270 |
5×120 | 1.2 | 2.4 | 46.2 | 2430 | 0.253 | 3.5 | 285 | 310 |
5×150 | 1.4 | 2.6 | 50.8 | 3036 | 0.206 | 3.5 | 325 | 345 |
5×185 | 1.6 | 2.8 | 56.6 | 3716 | 0.164 | 3.5 | 375 | 390 |
5×240 | 1.7 | 3 | 62.8 | 4677 | 0.125 | 3.5 | 440 | 450 |
5×300 | 1.8 | 3.2 | 71.4 | 5758 | 0.1 | 3.5 | 505 | 515 |
3 + 1 Core Aluminium Power Cable | ||||||||
Nom.Cross-bagian tina konduktor | Ketebalan insulasi | Ketebalan Sarung | Kira-kira.OD | Kira-kira Beurat | Max.Résistansi DC tina konduktor (20 ° C) | Tes Tegangan AC | Peunteun ayeuna | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV/5 mnt | Dina hawa (A) | Dina taneuh (A) |
3×4 + 1×2,5 | 0.7 | 1.8 | 12.7 | 189 | 7.41 | 3.5 | 34 | 45 |
3×6 + 1×4 | 0.7 | 1.8 | 13.9 | 224 | 4.61 | 3.5 | 43 | 57 |
3×10 + 1×6 | 0.7 | 1.8 | 16.4 | 311 | 3.08 | 3.5 | 60 | 77 |
3×16 + 1×10 | 0.7 | 1.8 | 19.2 | 418 | 1.91 | 3.5 | 83 | 105 |
3×25 + 1×16 | 0.9 | 1.8 | 22.5 | 557 | 1.2 | 3.5 | 105 | 125 |
3×35 + 1×16 | 0.9 | 1.8 | 25 | 667 | 0.868 | 3.5 | 125 | 155 |
3×50 + 1×25 | 1 | 1.8 | 25.5 | 833 | 0.641 | 3.5 | 160 | 185 |
3×70 + 1×35 | 1.1 | 1.9 | 28.9 | 1096 | 0.443 | 3.5 | 200 | 225 |
3×95 + 1×50 | 1.1 | 2.1 | 35.3 | 1448 | 0.32 | 3.5 | 245 | 270 |
3×120 + 1×70 | 1.2 | 2.2 | 37.1 | 1787 | 0.253 | 3.5 | 285 | 310 |
3×150 + 1×70 | 1.4 | 2.3 | 41.7 | 2143 | 0.206 | 3.5 | 325 | 345 |
3×185 + 1×95 | 1.6 | 2.5 | 45.3 | 2629 | 0.164 | 3.5 | 375 | 390 |
3×240 + 1×120 | 1.7 | 2.7 | 51.3 | 3314 | 0.125 | 3.5 | 440 | 450 |
3×300 + 1×150 | 1.8 | 2.9 | 56.3 | 4062 | 0.1 | 3.5 | 505 | 515 |
3×400 + 1×240 | 2 | 3.1 | 67.6 | 5295 | 0,0778 | 3.5 | 570 | 575 |
3 + 2 Core Aluminium Power Cable | ||||||||
Nom.Cross-bagian tina konduktor | Ketebalan insulasi | Ketebalan Sarung | Kira-kira.OD | Kira-kira Beurat | Max.Résistansi DC tina konduktor (20 ° C) | Tes Tegangan AC | Peunteun ayeuna | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV/5 mnt | Dina hawa (A) | Dina taneuh (A) |
3×4 + 2×2,5 | 0.7 | 1.8 | 13.5 | 208 | 7.41 | 3.5 | 34 | 45 |
3×6 + 2×4 | 0.7 | 1.8 | 14.8 | 249 | 4.61 | 3.5 | 43 | 57 |
3×10 + 2×6 | 0.7 | 1.8 | 17.4 | 343 | 3.08 | 3.5 | 60 | 77 |
3×16 + 2×10 | 0.7 | 1.8 | 20.5 | 465 | 1.91 | 3.5 | 83 | 105 |
3×25 + 2×16 | 0.9 | 1.8 | 24 | 625 | 1.2 | 3.5 | 105 | 125 |
3×35 + 2×16 | 0.9 | 1.8 | 25.7 | 728 | 0.868 | 3.5 | 125 | 155 |
3×50 + 2×35 | 1 | 1.9 | 29 | 980 | 0.641 | 3.5 | 160 | 185 |
3×70 + 2×35 | 1.1 | 2 | 33.8 | 1284 | 0.443 | 3.5 | 200 | 225 |
3×95 + 2×50 | 1.1 | 2.2 | 37.4 | 1660 | 0.32 | 3.5 | 245 | 270 |
3×120 + 2×70 | 1.2 | 2.3 | 42.8 | 2089 | 0.253 | 3.5 | 285 | 310 |
3×150 + 2×70 | 1.4 | 2.4 | 45.2 | 2424 | 0.206 | 3.5 | 325 | 345 |
3×185 + 2×95 | 1.6 | 2.6 | 50.6 | 3010 | 0.164 | 3.5 | 375 | 390 |
3×240 + 2×120 | 1.7 | 2.8 | 56 | 3772 | 0.125 | 3.5 | 440 | 450 |
3×300 + 2×150 | 1.8 | 3 | 64.6 | 4673 | 0.1 | 3.5 | 505 | 515 |
4 + 1 Core Aluminium Power Cable | ||||||||
Nom.Cross-bagian tina konduktor | Ketebalan insulasi | Ketebalan Sarung | Kira-kira.OD | Kira-kira Beurat | Max.Résistansi DC tina konduktor (20 ° C) | Tes Tegangan AC | Peunteun ayeuna | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV/5 mnt | Dina hawa (A) | Dina taneuh (A) |
4×6 + 1×4 | 0.7 | 1.8 | 15 | 259 | 4.61 | 3.5 | 43 | 57 |
4×10 + 1×6 | 0.7 | 1.8 | 17.7 | 364 | 3.08 | 3.5 | 60 | 77 |
4×16 + 1×10 | 0.7 | 1.8 | 20.3 | 490 | 1.91 | 3.5 | 83 | 105 |
4×25 + 1×16 | 0.9 | 1.8 | 24.2 | 665 | 1.2 | 3.5 | 105 | 125 |
4×35 + 1×16 | 0.9 | 1.8 | 26.4 | 803 | 0.868 | 3.5 | 125 | 155 |
4×50 + 1×25 | 1 | 1.9 | 32.6 | 1114 | 0.641 | 3.5 | 160 | 185 |
4×70 + 1×35 | 1.1 | 2.1 | 37.4 | 1806 | 0.443 | 3.5 | 200 | 225 |
4×95 + 1×50 | 1.1 | 2.2 | 42.4 | 2211 | 0.32 | 3.5 | 245 | 270 |
4×120 + 1×70 | 1.2 | 2.4 | 47.9 | 2677 | 0.253 | 3.5 | 285 | 310 |
4×150 + 1×70 | 1.4 | 2.5 | 51.9 | 3135 | 0.206 | 3.5 | 325 | 345 |
4×185 + 1×95 | 1.6 | 2.7 | 58 | 4038 | 0.164 | 3.5 | 375 | 390 |
4×240 + 1×120 | 1.7 | 2.9 | 65.1 | 4919 | 0.125 | 3.5 | 440 | 450 |
4×300 + 1×150 | 1.8 | 3.1 | 72 | 5957 | 0.1 | 3.5 | 505 | 515 |
FAQ
Q: Naha urang tiasa gaduh logo atanapi nami perusahaan pikeun dicitak dina produk atanapi bungkusan anjeun?
A: The OEM & ODM urutan téh warmly wilujeng sumping sarta kami boga pangalaman pinuh suksés di proyék OEM.Naon deui, tim R&D kami bakal masihan anjeun saran profésional.
Q: Naon istilah pembayaran?
A: 30% T / T deposit, 70% T / T kasaimbangan pembayaran saméméh kiriman.
Q: Kumaha pabrik anjeun ngalakukeun ngeunaan kadali kualitas?
A: Urang boga sistem kadali kualitas ketat, sarta ahli profésional urang bakal pariksa penampilan sarta uji fungsi sadaya item urang saméméh kiriman.
Q: Kumaha carana abdi tiasa sampel pikeun nguji kualitas anjeun?
A: Urang bisa nyadiakeun sampel bébas pikeun test anjeun sarta mariksa, ngan perlu nanggung muatan angkutan barang.